GE SR750 PDF

GE MULTILIN SR FEEDER MANAGEMENT RELAY NEW VAC. General Electric P5-G5-S5-HI-AR-E. General Electric GE MULTILIN SR GE MULTILIN SR FEEDER MANAGEMENT RELAY NEW VAC, WITH CASE. General Electric P5-G5-S5-HI-AR-T-H. General Electric GE. Find great deals for GE Multilin Feeder Management Relay Sr Shop with confidence on eBay!.

Author: Mikara Voodoorisar
Country: Mexico
Language: English (Spanish)
Genre: Life
Published (Last): 19 March 2018
Pages: 173
PDF File Size: 12.15 Mb
ePub File Size: 12.73 Mb
ISBN: 916-3-26224-123-3
Downloads: 5854
Price: Free* [*Free Regsitration Required]
Uploader: Zulkirn

Convenient COMTRADE and Sequence er750 Events viewers are an integral part of the Setup software included with every relay, to carry out postmortem event analysis to ensure proper protection system operation.

Simply remove the terminal blocks and then remove the SR chassis from the panel. User Interface Various user interfaces facilitate operation of the Analog Inputs Any external quantity may be monitored via an auxiliary current input. Gge baud rate of all the serial ports is variable from to 19, bps. This easy to use relay provides comprehensive protection functions for feeders and back up protection for bus, transformers and transmission lines at a reduced product life cycle cost.

GE Multilin 750 Feeder Management Relay Sr750

Traditionally, retrofitting an existing relay has been a challenging, time consuming task often requiring re-engineering, new drawings, panel modifications, re-wiring and re-testing. Load shedding schemes based on voltage and frequency elements Back-up protection for transmission lines, feeders and transformers Distributed Generation DG interconnect protection.

sr570 The VT failure feature monitors each phase of input voltage, generating an alarm and sending the programmed output signals when a failure is detected. Event Recording The relay captures and stores the last events, recording the time, date, cause, and system parameters. When the measured quantity exceeds the pickup level, the relay can trigger an alarm or signal an output. Trip Counter The number of breaker trip operations is recorded, and can be displayed for statistical purposes useful for units without operation counters.

  KOLOIDNA HEMIJA PDF

Trace memory recording can be triggered by operation of selected features ye logic inputs.

An alarm is also generated if the relay detects that the supervisory trickle current is not present. Two analog input level monitoring elements and two rate-of-change elements srr750 available. Events may be recorded selectively by category, so that only events of interest are recorded.

Breaker Conditions The relay calculates the per-phase wear on the breaker contacts to establish a threshold. Insert the new 8 Series Retrofit chassis into the switchgear and simply plug-in the old terminal blocks – there is no need to make any cut-out modifications or push and pull cables.

When the breaker maintenance threshold is exceeded the relay can trigger an alarm.

The number of breaker trip operations is recorded, and can be displayed for statistical purposes useful for units without operation counters. The amount of pre-event data recorded is set by the user. The can display 30 user-selected messages xr750 keypad inactivity.

General Electric GE MULTILIN SR FEEDER MANAGEMENT RELAY NEW

A failure to respond to an open or close signal in a programmed time can be used to generate an alarm. A block of configurable volatile memory can be used for recording samples of the AC input voltages and current, and the status of logic inputs and output relays. As an alternative, please refer to the relay.

Grid Solutions helps enable utilities and industry to effectively manage electricity from the point of generation to the point of consumption, helping to maximize the reliability, efficiency and resiliency of the grid.

  ALFA LAVAL LKB PDF

A 40 character display allows access to setpoints, actual values, and diagnostic messages generated by a trip or alarm condition. About Grid Solutions GE’s Grid Solutions business serves customers globally with over 17, employees in approximately 80 countries.

Any external quantity may be monitored via an auxiliary current input. Oscillography A block of configurable volatile memory can be used for recording samples of the AC input voltages and current, and the status of logic inputs and output relays.

GE SR750 Multilin Power Management Reconditioned

VT Failure The VT failure feature monitors each phase of input voltage, generating an alarm and sending the programmed output signals when a failure is detected. Indicators Twenty LEDs indicate relay status, system status, and trip and alarm conditions.

The front panel port allows easy local computer access. The relay calculates the per-phase wear on the breaker contacts to establish a threshold.

A rear Ethernet port is also available as an optional feature. With the new 8 Series Retrofit Kit users are able to install the Feeder Management System without modifying existing cutouts and wiring, and without any drawing changes or re-engineering time.

Display A 40 character display allows access to setpoints, actual values, and diagnostic messages generated by a trip or alarm condition. The relay captures and stores the last events, recording the time, date, cause, and system parameters.

No need to disconnect any of the field wiring.